Use normal fire caution procedures when using any petroleum cleaner. We are committed to ensuring that the individuals whose details we hold understand our privacy practices. Download or purchase owners manuals for honda pumps. The 1580 series fire pumps are designed to provide water to stand pipe, sprinkler, chemical mitigation and hydrant systems for fire suppression in industrial and commercial facilities. Rosenbauer offers truckmounted fire pumps ranging from 750 lmin to 11,000 lmin and with these pumps covers both normal pressure with 10 bar as well as the highpressure range of applications with 40 bar. Advanced fire training manual potter electric signal. The vertical design requires 30% less space than a traditional horizontal design. Parts manual flex series single stage booster pumps fsgmnl. Davey water pump systems torrium 2 installation and operating instructions guide davey water pump systems torrium 2 data brochure and catalog. Fire pump operation manual free download as pdf file. Centrifugal fire pump principles of operation, inspection. The most important aspect of fire protection package is the reliability of the fire fighting pumping system to ensure adequate water supply at required pressure at.
Explosion andor seizure of pump can cause fire andor burns. If the pump or motor is damaged or leaking, electric shock, fire, explosion, liberation of toxic fumes, physical harm, or environmental damage may result. Centrifugal fire pump principles of operation, inspection tests and troubleshooting guide. Afixed oil level is maintained within the power frame. For darley porpoise floating fire pump do not use this pump for hose testing.
This manual should accompany the fire pump if sold to another person. Indian standard installation and maintenance of fire. This manual must be read and understood before installation and startup. A pump runaway valve h shuts off the air to the pump if the pump accelerates beyond the preadjusted setting. This instruction manual covers several different pump models. Standard manuals include product description and specifications, installation, operation, calibration, and programming procedures. Fire pumps peerless pump offers fire pumps, process pumps, industrial pumps, vertical pumps, horizontal pumps, selfpriming pumps and industrial pumps. Parts manual flex series single stage booster pumps fsgmnl00185 rev a. The material referenced can be found in ifsta pumping. Installation, operation, and maintenance manual goulds pumps. Such testing could result in major pump or engine damage. Armstrong horizontal endsuction hes fire pumps deploy a heavyduty bearing frame to provide long and reliable service in an overhung impeller design. For special options, supplemental instructions are available.
Run fire pumps weekly and record results in the appropriate column. This manual provides information for the correct safety, installation, operation, maintenance, repair. The fire pump delivers the water via the pipesystem to the fire sprinklers to suppress the fire. Firefighting equipment, pumps, and firetrucks located in itasca illinois. Performance tests each pump produced, undergoes performance testings as follows a operation test. Introduction the first standards for fire detection and alarm systems in the united states dates back to the 1800s. The jockey pump stop point should equal the pump churn pressure plus the minimum sta tic supply pressure. Preparations for pumping make sure to read the engine instruction manual before use. Kirloskar brothers limited has been supplying fire protection packages for many decades. Advanced fire training manual 8700055 rev h 0517 section 1. Cummins fire pump users guide cummins learning center. This course is a sixteen 16 hour noncertification course intended to give firefighting personnel the basic understanding of fire department pump operations.
The innovative armstrong series 4600 hsc pump is designed to allow easy maintenance. In a fire installation there can be one or more fire pumps put into operation as a duty assist 50% and standby pumps. Oil lubrication oil lubricated bearings are optional on some model 411 series pumps. In particular, we want to make sure that we are respectful of your data protection preferences, and that you understand your data privacy rights. Search in aurora pump catalogs and technical brochures on directindustry and find the information you need in 1 click. Published manuals click on the manual title to open the newest revision of the manual. Technical manuals view the latest pump technical manuals. Waterax ministriker owners manual 2 032015 important safety instructions it is recommended that all information provided in this manual be carefully read and understood before performing any operation of or maintenance to the pump. Every pump operators basic equation fire engineering. Installation and operating instructions horizontal split case fire pumps. In a basic centrifugal pump, typically a single casing, water enters through the pump inlet into the center eye of the impeller which is spinning on a shaft. Select ac fire pump is here to help make specific pump selections and give easy access to technical product data, performance curves, dimensional drawings, operational and maintenance manuals all in one easy to use tool. Never apply heat to aid in their removal unless explicitly stated in this manual.
Fire pumps, fire apparatus, fire and defense equipment. Centrifugal pump design is the most typical for fire pumps and auxiliary pumps in modern fire apparatus and its proven design has been used in fire apparatus for well over a century. Darley fire pumps, apparatus, water systems, robotics. Literature library ac fire pumps xylem applied water. Fire pumps are typically listed by an approval institute and can be driven either by an electric motor or diesel engine. The pumps same level suction and discharge permits easypiping layout and pump installation. Diesel engines for nfpa20 fire protection applications. Model 3393 installation, operation, and maintenance manual. View and download armstrong 4380 installation and operating instructions manual online. Explosion and or seizure of pump can cause fire andor burns. This manual contains information for the correct oper ation and maintenance of a cummins fire pump. Ac fire pump xylem applied water systems united states.
Fire pump operation manual pump bearing mechanical scribd. Service bulletin sb157 miv repair quick guide for switch replacement. All pumps sales and service has been the leading supplier of industrial pumps for over 45 years. Take apart our fire suppression equipment with the click of your mouse. Refer to the drawing and parts list in the back of this manual.
By navigating our website, you accept our use of cookies. M manual pull start e electric push button start twin two impellers 1d one discharge line 2d and emergency environmentstwo discharge lines highvolume pumps our products are designed in use of fire portable pumps the flow starts here powerful, portable, pumps 2 visit us at fire pump. The right pump for every application can be chosen. Peerless pump offers fire pumps, centrifugal pumps. Lighting products have separate safety summary and installation sheets. Installation,operation, andmaintenancemanual goulds pumps. We use cookies to improve your experience on this site and show you personalized advertising. Armstrong 4380 installation and operating instructions manual.
An automatic start is controlled by a pressure switch or by remote automatic devices. Ac fire pump offers a range of vertical inline pumps. Such damage may cause overheating of the engine andor pump and bodily harm. The first step on the way to the optimal pump is the selection between a centrifugal pump or a positive displacement pump. Date description of changes a april 2016 initial release b november 2016 update text so manual can be used with non.
Whether were meeting stringent customer standards, unheardof deadlines or just going the extra mile to ensure customer satisfaction, more and more customers are choosing pattersons sentinel series fire pump products and services to securely fulfill their fire. Ac pump, a division of itt corporation, manufactures high quality centrifugal pumps and parts for the global industrial and municipal markets. Only overspeed shutdown or a signal from the diesel controller will shut down an. Fire pump sizing the estimated performance of the fire pump between 100% and 150% of rated flow can be calculated using the following formula. Fire pump controller and product manuals tornatech. Pdf instruction manual for fire pump ioannis sozos. View and download fire pump 8100 series installation, operation and maintenance manual online. This manual provides instructions for the installation, operation, and maintenance of the ac fire pumps. Every pump operators basic equation by paul spurgeon continuing education course to earn continuing education credits, you must successfully complete the course examination. This is important because our fire apparatus have the ability to pump on average up to 1,000 gallons per minute at a large. B8796 self priming pump maintenance manual f8196 8196 low flow impeller mailer brochure.
Stocking and supplying the largest range of industrial pumps. The difference lies on one hand in the principle of transpor. We offer efficient, operationally safe, lownoise pumps for your processes and this manual shall help you to make the right choice. Pl831 suction and discharge fitting reference shee. At a fire, it is usually difficult for the pump operator to observe the pump closely enough to determine its true condition. While these first fire alarms were simplistic, advances in technology have resulted in fire alarm systems that can be intimidating in their complexity. Vertical turbine fire pumps patterson pump company.
47 1233 550 206 1481 563 705 795 607 593 495 1430 383 1179 751 785 878 174 650 640 1368 191 728 464 64 204 673 1072 71 103 1086 1010 1188 644 290 962